Saturday, January 1, 2011

Re-testing of raw materials and intermediates


1.0        Purpose   :    To provide an instruction for re-testing of raw materials and intermediates.
2.0          Objective: To provide a documented procedure for re-testing of raw materials and intermediates.
3.0            Scope  :   This procedure is applicable for re-testing of raw materials and intermediates in QC department.
4.0        Responsibility  :
·       Primary   : QC Chemist / QC Officer
·       Secondary : Overall: QC – Incharge
 Procedure:
·        After the receipt of re-testing intimation note from store department, QC Chemist takes its entry in the respective Re-testing logbook and gives AR No. to raw materials or intermediate.
·         AR No. Should be given as follows
  For Raw material: R-XXX/ZZ/R1 (e.g. R-001/08/R1)
  Where, R         = raw material
                XXX    = serial no. (e.g. 001, 002, ….)
                ZZ        = year (e.g. 2008 as 08)
                R1       = re-test first time (e.g. R1, R2, ….)
Collect samples as per sampling plan.
·        After completion of sampling, do the necessary critical tests (e.g. assay, LOD, water content, pH, specific optical rotation etc.) as per the Standard Analytical Procedure.
·        Raw material may also be approved on the basis of physical appearance.
·        After completion testing, put the status of approved / rejected on the containers.
·        Re-testing of any raw materials should be four times only.
·        Frequency of re-testing for raw material is every year, and for intermediate is every six months. 
·        Re-testing should be performing on first come first out basis. The re-testing of material   should carry out, whose due date for re-test is earlier. 